Characteristic

Magnetic Latching Relay Outline Dimension:19.0×15.5×15.8mm 15A of switching capability Contact: 1 Form A, 1 Form C Only pulse excitation,single and double coil work available Dielectric strength of 2700V between coil and contacts Friendly product(RoHS Compliant)

  • Authentication
  • Naming rules
  • Specifications
  • Outline, Wiring, Installation Hole Diagram
  • Product Packaging Specifications
  • Characteristic curve
  • Coil Specification Table
  • Authentication
    • Commodity name: HKE19
    • Commodity ID: D-006
    • 触点形式: 1 Form A, 1 Form C
    • 触点负载: C:NO/NC:10A/5A 277VAC(Res) A:10A 277VAC(Res) TV-8 250VAC(NO )
    • 线圈功率: Coil Power for single coil(L1): 0.25W, 0.4W Coil Power for double coil(L2): 0.45W, 0.8W

    Magnetic Latching Relay Outline Dimension:19.0×15.5×15.8mm 15A of switching capability Contact: 1 Form A, 1 Form C Only pulse excitation,single and double coil work available Dielectric strength of 2700V between coil and contacts Friendly product(RoHS Compliant)

  • Naming rules

  • Specifications

    CONTACT DATA

    Contact Form

    1 Form A, 1 Form C

    Contact Material

    Ag Alloy

    Contact Rating

    C:NO/NC:10A/5A 277VAC(Res) A:10A 277VAC(Res) TV-8 250VAC(NO )

    Contact Resistance

    Max. 100mΩ(6VDC 1A)

     

    Load

    Max. Switching Voltage

    277VAC/30VDC

    Max. Switching Current

    15A(1 Form A) 10A(1 Form C)

    Min. Switching Load

    2770VAC/300W

     

    Life

    Electrical

    2.5×104 operations (TV-8,40C)

    5×104 operations (NO/NC:10A/5A 277VAC ON/OFF:1S/9S,85C)

    Mechanical

    1×107   operations

     

    COIL DATA

     

    Coil Power for single coil(L1)

    0.25W,0.4W

    Coil Power for double coil(L2)

    0.45W,0.8W

     

     

    GENERAL DATA

    Insulation Resistance

    Min.100MΩ  500VDC

    Dielectric Strength

    Between open contacts

    750VAC,50/60Hz,1min

    Between coil and contacts

    2,700AC,50/60Hz,1min

    Between coil and contacts

    4,000AC,50/60Hz,1sec

    Operate Time

    Max.8ms

    Reset Time

    Max.5ms

    Operating Temperature

    -40C to +85C

    Humidity

    5~85% R.H

    Shock

    Resistance

    Endurance

    980m/s

    Misoperation

    98m/s

    Vibration    Resistance

    Endurance

    10~55Hz,1.5mmdouble amplitude

    Misoperation

    10~55Hz,1.5mmdouble amplitude

    Weight

    Approximately 9g

     

    Note: The above values are initial values.

    Precautions:
    1.The magnetic latching relay is in the reset state of initial value,
    but it may become the set state due to the impact of transportation
    or installation. Therefore, before using it (when the power is
    connected), please check the status of the relay.
    2.In order to ensure the set or reset of the magnetic latching relay,
    the excitation voltage applied to the coil must reach the rated
    voltage, and the pulse width must be greater than 100ms,do not
    apply voltage to the set coil and reset coil at the same time, do not
    apply voltage to the coil for a long time (more than 1 minute).
    3.In the process of product transportation, storage and application,
    please keep the product away from strong magnetic field to avoid
    the change of set and reset voltage.

     

  • Outline, Wiring, Installation Hole Diagram

  • Product Packaging Specifications

    Product number

    Inner packing

    Carton specifications length × width × height (mm)

    Total quantity (only)

    Net weight(Kg)

    Gross weight (Kg)

    HKE19

    25 pcs/tube

    456×266×161

    1000/box

    9.0

    10.4

  • Characteristic curve
  • Coil Specification Table

HKE19
  • Authentication
  • Naming rules
  • Specifications
  • Outline, Wiring, Installation Hole Diagram
  • Product Packaging Specifications
  • Characteristic curve
  • Coil Specification Table
    • Commodity name: HKE19
    • Commodity ID: D-006
    • 触点形式: 1 Form A, 1 Form C
    • 触点负载: C:NO/NC:10A/5A 277VAC(Res) A:10A 277VAC(Res) TV-8 250VAC(NO )
    • 线圈功率: Coil Power for single coil(L1): 0.25W, 0.4W Coil Power for double coil(L2): 0.45W, 0.8W

    Magnetic Latching Relay Outline Dimension:19.0×15.5×15.8mm 15A of switching capability Contact: 1 Form A, 1 Form C Only pulse excitation,single and double coil work available Dielectric strength of 2700V between coil and contacts Friendly product(RoHS Compliant)

  • Naming rules

  • Specifications

    CONTACT DATA

    Contact Form

    1 Form A, 1 Form C

    Contact Material

    Ag Alloy

    Contact Rating

    C:NO/NC:10A/5A 277VAC(Res) A:10A 277VAC(Res) TV-8 250VAC(NO )

    Contact Resistance

    Max. 100mΩ(6VDC 1A)

     

    Load

    Max. Switching Voltage

    277VAC/30VDC

    Max. Switching Current

    15A(1 Form A) 10A(1 Form C)

    Min. Switching Load

    2770VAC/300W

     

    Life

    Electrical

    2.5×104 operations (TV-8,40C)

    5×104 operations (NO/NC:10A/5A 277VAC ON/OFF:1S/9S,85C)

    Mechanical

    1×107   operations

     

    COIL DATA

     

    Coil Power for single coil(L1)

    0.25W,0.4W

    Coil Power for double coil(L2)

    0.45W,0.8W

     

     

    GENERAL DATA

    Insulation Resistance

    Min.100MΩ  500VDC

    Dielectric Strength

    Between open contacts

    750VAC,50/60Hz,1min

    Between coil and contacts

    2,700AC,50/60Hz,1min

    Between coil and contacts

    4,000AC,50/60Hz,1sec

    Operate Time

    Max.8ms

    Reset Time

    Max.5ms

    Operating Temperature

    -40C to +85C

    Humidity

    5~85% R.H

    Shock

    Resistance

    Endurance

    980m/s

    Misoperation

    98m/s

    Vibration    Resistance

    Endurance

    10~55Hz,1.5mmdouble amplitude

    Misoperation

    10~55Hz,1.5mmdouble amplitude

    Weight

    Approximately 9g

     

    Note: The above values are initial values.

    Precautions:
    1.The magnetic latching relay is in the reset state of initial value,
    but it may become the set state due to the impact of transportation
    or installation. Therefore, before using it (when the power is
    connected), please check the status of the relay.
    2.In order to ensure the set or reset of the magnetic latching relay,
    the excitation voltage applied to the coil must reach the rated
    voltage, and the pulse width must be greater than 100ms,do not
    apply voltage to the set coil and reset coil at the same time, do not
    apply voltage to the coil for a long time (more than 1 minute).
    3.In the process of product transportation, storage and application,
    please keep the product away from strong magnetic field to avoid
    the change of set and reset voltage.

     

  • Outline, Wiring, Installation Hole Diagram

  • Product Packaging Specifications

    Product number

    Inner packing

    Carton specifications length × width × height (mm)

    Total quantity (only)

    Net weight(Kg)

    Gross weight (Kg)

    HKE19

    25 pcs/tube

    456×266×161

    1000/box

    9.0

    10.4

  • Characteristic curve
  • Coil Specification Table

Keyword:

Signal relay

Power relay

Automotive relay

Magnetic latching relay

Solid state relay

New energy relay

Messages online


* is a required field! You can inquire about any issues within the company, including products. Please be sure to fill in the correct contact information so that we can reply to you in a timely manner!